Facebook Login JavaScript Example
3M Construction Assembling & Trading Co., Ltd

THE MORE PROFESSIONAL, THE SAFER!

  • Tiếng Anh
  • Tiếng Việt
+84 903 815 852 - +84 225 3 564 259

Contact us 24/7

119/81 Nguyen Trai street, Ngo Quyen district, Hai Phong city, Vietnam

Our address

Installation of more than a LPG cylinder

Views: 1992

Irregardless of their capacity, LPG cylinders must be located outside residential buildings. They must be used standing upright on a flat, horizontal and non-combustible surface. They must not be located in basements, cellars or locale below ground level.

Cylinder walls must be located at the required distances from openings, sewers, air holes, etc. These distances depend on the capacity stored.

Role of the automatic or manual diverter valve: first expansion

It  is  used  to  connect  several  cylinders  together  (cylinders  in  service  and  cylinders  in reserve), to regulate  cylinder outlet pressure  at  1.5 bars.

It is  used  to  switch  empty  in-service  cylinders  or  those  that  no longer  ensure flow  to the  cylinders  in  reserve.